Site
GM-SCADA
Kynatron Technologies
16Channels
14Normal
2Alarms
LIVE
00:00:00
Admin
Batch #2847
Uptime 847d
Storage 9.7%
CPU 42°C
-42dBm
Updated 0s ago
Overview
Dashboard
Monitoring
Alarms2
Logs
Operations
Control
Reports
Diagnostics
Inventory
System
Configuration
Scheduler
Calibration
Admin
v2.1.0 | GM-DL Pro 16CH
Real-time overview of all zones. Quickly spot anomalies and track production flow at a glance.
Zone 1 Furnace OK
842°C
CH-1 K-TCSP 850°C
Zone 2 Kiln HIGH
1038°C
CH-2 K-TCSP 980°C
Zone 3 Cooling OK
127°C
CH-3 RTDSP 130°C
RH Ambient WARN
62%
CH-5 CapLimit <55%
PROCESS FLOW RAWINPUT ZONE 1842°CFURNACE ZONE 21038°CKILN ZONE 3127°CCOOLING FINISHEDOUTPUT Today:1,247 units/ 1,500 target (83%)
Real-Time Process Trend 60 min • 1s sample
System Load
Zone 1
Heater Output
Zone 2
Critical
Fan Speed
Cooling
Storage
128 GB SD
Deep-dive into channel data. Use the trend chart to identify patterns and channel cards for instant status of each measurement point.
CH-1 • K-Type Thermocouple
Zone 1 Furnace
OK
842°C
SP: 850°C Dev: -0.9% Temp
CH-2 • K-Type Thermocouple
Zone 2 Kiln
HIGH
1038°C
SP: 980°C Dev: +5.9% Temp
CH-3 • RTD Pt100
Zone 3 Cooling
OK
127°C
SP: 130°C Dev: -2.3% Temp
CH-4 • K-Type Thermocouple
Zone 4 Annealing
OK
618°C
SP: 600°C Dev: +3.0% Temp
CH-5 • Capacitive Sensor
Ambient Humidity
WARN
62%RH
Limit: <55% +12.7% Humidity
CH-6 • NTC 10K Thermistor
Ambient Temperature
OK
28°C
Limit: <35°C Normal Temp
CH-7 • 4-20mA Transmitter
Line Pressure
OK
4.2bar
SP: 4.5 bar Dev: -6.7% Pressure
CH-8 • K-Type Thermocouple
Preheat Chamber
OK
410°C
SP: 420°C Dev: -2.4% Temp
CH-9 • 0-10V Analog
Motor Current
OFF
A
Voltage/CurrentDisabled
Multi-Channel Trend [1h] [6h] [12h] [24h]
All active and historical alarms. Acknowledge critical events to confirm operator awareness and maintain audit compliance.
2Active
1Ack'd
23Today
20Cleared
Sound ON
Zone 2 HIGH ALARM — 1038°C > SP 980°C (+5.9%)
14:32:08 | CH-2 | Unacknowledged
Humidity Warning — 62% RH > 55% limit
14:28:45 | CH-5 | Acknowledged
Rate-of-rise alarm — Zone 2 rising 2.1°C/min (limit 1.5)
13:58:22 | CH-2 | Pre-alarm
Batch #2847 started — continuous logging active on 14 channels
14:15:00 | System
Zone 1 returned to normal — within ±1% of SP
13:45:10 | Auto-cleared
Calibration due: CH-5 in 48 hours
13:30:00 | Maintenance
Complete audit trail of all recorded data. Filter by channel, export for analysis, and verify data integrity for regulatory compliance.
#2847Batch
4h 32mDuration
16,320Samples
OKIntegrity
Filter:Showing 1-20 of 16,320
TimeChValueUnitStatus
Operate equipment and tune process parameters. PID status shows closed-loop control health. Use setpoints to regulate temperatures.
Relay Outputs
Furnace Heater
R1 · 30A/240V
Cooling Fan Bank
R2 · 15A/240V
Exhaust Damper
R3 · Motorized
Conveyor Belt
R4 · VFD 50Hz
Gas Solenoid
R5 · N/C Safety
E-STOP
All OFF · Safety interlock
Setpoints
Zone 1 °C
Zone 2 °C
Zone 3 °C
RH Limit %
Sample Rate sec
PID Loops
AUTO
Zone 1
82%
PV:842 SP:850
MANUAL
Zone 2
96%
PV:1038 SP:980
AUTO
Zone 3
45%
PV:127 SP:130
Shift summaries and OEE metrics. Generate reports for management review, quality audits, and regulatory submission.
Shift Summary (06:00–14:00)
ChannelMinMaxAvgσResult
Zone 1835°862°847°±4.2PASS
Zone 2965°1042°1005°±18.7FAIL
Zone 3118°134°126°±3.1PASS
RH52%67%59%±4.5WARN
OEE
78.4%
Availability 92% × Performance 89% × Quality 96%
Downtime Events
13:58 – Zone 2 high (4m)Unplanned
10:30 – Conveyor jam (8m)Unplanned
09:00 – Shift change (15m)Planned
Sensor health and connectivity checks. Identify degrading sensors before they cause measurement errors or production losses.
System Diagnostics
Sensor Health
CH-1 K-TC● Healthy
CH-2 K-TC● Healthy
CH-3 RTD● Healthy
CH-5 RH● Cal Due
CH-15● Disabled
CH-16● Disabled
Signal Quality
CH-1 Noise0.02°C RMS
CH-2 Noise0.04°C RMS
CH-3 Noise0.01°C RMS
CH-5 Noise0.3% RMS
Input Impedance>10 MΩ (all)
Connectivity
WiFiConnected
MQTT BrokerConnected
NTP Sync±12ms
Cloud Latency48ms
Last Packet2s ago
Load vendor presets or build custom configurations. Ensure compliance with industry-specific standards (Pharma, Food, Metal, Cold Chain).
Configuration
Vendor Presets Add Vendor
Pharma (21 CFR Part 11) loaded — Sample: 1s, Logging: Continuous, Audit trail: ON, e-Signatures: Required, Data format: CSV with checksum, Retention: 5 years min
Channel Config ● Pharma preset active
ChNameTypeRangeHiLoDeadbandLog
1K-TC0–1024°CON
2K-TC0–1024°CON
3RTD-200–500°CON
5Cap0–100%ON
Network
IP192.168.1.100
Gateway192.168.1.1
SSIDKT-FACTORY-5G
MQTTmqtt.kynatron.com:8883
NTPpool.ntp.org
Web HMI:80 (HTTP)
New Product Configuration Builder

Create a custom configuration for a new product/deployment

Product Name
Base Preset
Channel Count
Sample Rate
Connectivity
Compliance
Plan batches and maintenance windows. Stay ahead of calibration deadlines to avoid compliance gaps or unplanned downtime.
Schedule & Maintenance
Batch Schedule
BatchStartEndProductStatus
#284710:00Steel Rod ARunning
#284815:0022:00Steel Rod BScheduled
#2849Tomorrow 06:00Alloy Mix CPending
Calibration Schedule
CH-5 HumidityDue in 48h
CH-1 K-TCDue Jul 28
CH-2 K-TCDue Jul 28
CH-3 RTDDue Aug 05
All ChannelsAnnual: Jan 2027
Track spare parts and consumables. Avoid unplanned production stops due to unavailable replacement sensors or components.
Inventory Management
142In Stock
18Low Stock
3Out of Stock
23On Order
Spare Parts & Sensors
ItemPart No.StockMin QtyStatusReorder
K-Type Thermocouple ProbeKT-TC-K1002410OK
RTD Pt100 SensorKT-RTD-P10085OK
Capacitive RH ProbeKT-RH-C20035LOW
SD Card 128GB IndustrialKT-SD-128I125OK
Relay Module 30AKT-RLY-30A24LOW
Terminal Block 16-posKT-TB-16P06OUT
IP66 Cable Gland M20KT-CG-M204520OK
Fuse 5A/250V (pack 10)KT-F-5A1065OK
Pending Orders
PO-2847-01Terminal Blocks x20 ● In Transit
PO-2847-02RH Probes x10 ● Ordered
PO-2846-05Relay Modules x10 ● Ordered
Consumption (This Month)
Thermocouples6 used / 4 replaced
SD Cards2 rotated
Fuses3 blown (Zone 2)
Total Cost₹14,250
Track calibration status of all measurement channels and reference standards. Ensures traceability, accuracy, and regulatory compliance.
Calibration Management
16Total Sensors
11Calibrated OK
3Due Soon
2Overdue
Calibration Schedule
Part / SensorChTypeLast CalibratedNext DueStatusAction
Zone 1 Furnace ProbeCH-1K-TC2026-06-152026-09-15OK
Zone 2 Kiln ProbeCH-2K-TC2026-06-152026-09-15OK
Zone 3 Cooling RTDCH-3RTD Pt1002026-05-202026-08-20OK
Zone 4 Annealing ProbeCH-4K-TC2026-06-152026-09-15OK
Humidity SensorCH-5Capacitive2026-04-102026-07-10OVERDUE
Ambient Temp NTCCH-6NTC 10K2026-05-012026-08-01DUE SOON
Pressure TransmitterCH-74-20mA2026-03-222026-06-22OVERDUE
Preheat Zone ProbeCH-8K-TC2026-06-012026-09-01DUE SOON
Reference Std (Ice Point)REF-1Standard2026-01-152027-01-15OK
Reference Std (1000°C)REF-2Standard2026-01-152027-01-15OK
System RTC ClockSYSRTC/NTP2026-07-012026-10-01OK
Cold Junction Comp.INTInternal2026-06-152026-09-15DUE SOON
Requires Replacement
PartChService LifeIssueRecommendation
Humidity Probe (Cap.)CH-518 monthsAccuracy drift detected (±4.2% vs spec ±2%)Replace immediately — order KT-RH-C200
Pressure TransmitterCH-724 monthsZero offset +0.3 bar (recal attempted, persists)Schedule replacement within 30 days
Zone 2 ThermocoupleCH-214 monthsInsulation resistance degrading (2.1 MΩ, spec >5 MΩ)Monitor closely — replace at next shutdown
System management, user access control, and full audit trail. Ensures accountability and security across all operator actions.
System
ModelGM-DL Pro 16CH
SerialKT-2026-PRO-00142
Firmwarev2.1.0 ● Up to date
Uptime847d 14h 32m
CPU48°C | 12% load
RAM124 / 512 MB
LicensePro (Exp: Dec 2027)
Last BackupToday 06:00
User Management Add User
UserRoleLast LoginStatusAction
adminAdministratorToday 08:00Active
operator1OperatorToday 06:15Active
operator2OperatorJul 12Inactive
viewer_mgmtViewerYesterdayActive
maint_teamMaintenanceJul 10Active
Audit Trail
TimeUserActionDetail
08:00:12adminLoginWiFi (192.168.1.45)
06:15:30operator1LoginFront Panel
06:00:00SYSTEMBatch Start#2847 auto-trigger
05:55:00SYSTEMNTP SyncDrift ±8ms corrected
02:00:00SYSTEMBackup12.4 GB → SD card
Yesterday 22:00adminConfig ChangeZone 2 SP: 950→980°C
Yesterday 17:30viewer_mgmtLoginWeb HMI (10.0.0.5)
Role Permissions
PermissionAdminOperatorMaint.Viewer
View Dashboard
Control Equipment
Change Setpoints
Acknowledge Alarms
Edit Configuration
Manage Users
Factory Reset